Safety & Proper Use Guidelines
1. Maximum Pressure – Do Not Exceed 120 PSI
The Thumper is designed to operate with water pressure not exceeding 120 psi.
Operating above 120 psi may cause:
Cracking or rupture of the unit
Sudden separation at the connection point
Internal component failure
Possible water discharge or property damage
Always confirm system pressure before connecting the unit.
2. Water Only – No Air or Gas
The Thumper is designed for use with water only.
Do not use with:
Compressed air
Natural gas
CO₂
Chemicals
Any non-water fluid
Improper use can cause serious damage or failure.
3. Inspect the Plumbing System First
Before installing:
Inspect hose bibs, valves, and fittings for damage.
Do not attach to:
Cracked or brittle PVC
Sun-damaged pipe
Weak glue joints
Thin-wall or non-pressure-rated pipe
The vibration created by the Thumper may expose pre-existing weaknesses in aging or damaged piping.
If a pipe fails during use, it may indicate an existing structural issue.
4. Proper Attachment Is Required
Connect only to a free-standing hose bib or approved connection point.
Do not overtighten.
Do not cross-thread.
Hand tighten firmly and avoid excessive torque.
Overtightening may crack the housing or damage threads.
5. Do Not Modify the Unit
Do not disassemble.
Do not replace internal components.
Do not alter the spring or housing.
Do not use if visibly cracked or damaged.
Modifications void warranty and may create safety hazards.
6. Avoid Impact & Rough Handling
The Thumper housing is precision-manufactured using advanced polymer technology.
Do not drop.
Do not strike.
Do not expose to extreme heat.
Store out of prolonged direct sunlight.
Internal damage may not be visible but can reduce pressure tolerance.
7. Use Within Design Limits
The Thumper is:
✔ A pipe tracing vibration tool
✘ Not a leak detection device
✘ Not a pressure testing tool
✘ Not intended for permanent installation
Using the unit outside its intended purpose may damage both the device and the plumbing system.
8. Results Are Indicative, Not Guaranteed
Pipe locating depends on:
System condition
Water flow
Pipe material
Soil conditions
Operator skill
Results may vary.
The Thumper assists in tracing pipe paths but does not guarantee exact depth or location.
Always verify before excavation.
9. Monitor During Operation
Do not leave unattended while pressurized.
Shut off water immediately if:
Leaks occur
Excessive vibration is observed
The unit shifts or loosens
10. Commercial Use Disclaimer
The Thumper is intended for professional use by trained personnel.
Improper use may result in:
Equipment damage
Plumbing system damage
Water release
Property damage